SNOW MELTING SYSTEMS TORONTO
- Melts Snow As It Falls!
- Less Salt on Your Driveway!
- Runs Only When It Snows!
- Safer Steps All Winter!

| Cable Construction: | Twin conductor |
| Rated Voltage : | 120V,208V,240V,277V,347V,480V,600V |
| Output : | 12W/ft (40W/m) |
| Heating Element Size : | 35′(10.7m) to 940′(286.5 m) |
| Bending radius: | 1.5″ (38mm) |
| Cable Diameter: | 1/4″ (6.5mm) |
| Conductor Insulation: | Fluoropolymer and XLPE |
| Outer Insulation: | PVC |
| Max. rated Temp.: | 220℉(105℃) |
| Min. Installation Temp.: | 40℉(5℃) |
| Cold lead | 16ft length |
A heated driveway clears itself while you sleep. The snow controller switches the cable on as the first flakes land, so the surface stays wet instead of white, and you back out in the morning without shovelling, salting or waiting for a snow removal contractor. It also takes the risk out of reverse-slope driveways that lead down to a below-grade garage, common in older Toronto neighbourhoods, where a thin glaze of ice can stop a car from climbing to the street.
Snow melting mats have the heating cable pre-spaced on a mesh, so the output is even across the whole mat and installation goes quickly. They come in 2 ft and 3 ft widths, in 120V or 240V, and suit regular shapes such as straight driveways, walkways and parking pads. Mats cost more than loose cable for the same area, but they save time on site, which matters when the concrete crew is waiting to pour.
Loose snow melting cable handles the shapes mats cannot: curved and circular driveways, outdoor stairs and ramps. It comes in 120V and 240V, with 208V and 277V versions for commercial projects. Cable costs less than mats but takes longer to lay out, and the installer sets the spacing to reach the watts per square foot the design calls for, with tighter runs where more heat is needed, such as on stairs.
Full coverage heats the entire driveway and clears it edge to edge, but it has the highest energy demand. Two alternatives reduce that load. Zoning splits a large area into sections that heat one after another, which lowers the power drawn at any moment and can avoid a service upgrade. A tire-track layout heats two strips under the wheels, each roughly 18 to 24 inches wide, with the walkway and steps on a separate zone. Tracks work well in poured concrete; under pavers, design guides call for full coverage, because pavers beside a heated strip can settle unevenly. Call 1-877-523-5667, and we will lay out the option that fits your driveway and your budget.
Once commissioned, the system runs on its own. The controller turns the heat on when snow starts, holds the surface just warm enough to melt it and shuts off after the surface dries, so the driveway stays usable through the heaviest storm of the season without anyone stepping outside. Before the first snowfall each year, check that the sensors are clear of leaves and debris and that the controller is set to automatic.